Product Details
Data sheet
- Width
- 145 mm
- Height
- 220 mm
- Depth
- 455 mm
- Weight
- 19.6 g
- Operating temperature (T-T)
- 0 - 40 °C
- Operating relative humidity (H-H)
- 0 - 90%
- USB port
- Yes
- Battery recharge time
- 4 h
- Output power
- 2100 W
- Input frequency
- 50/60 Hz
- Display type
- LCD
- Chassis type
- Tower
- Input operation voltage (min)
- 162 V
- Power protection features
- Overvoltage protection
- Cold start
- Yes
- Output power capacity
- 3000 kVA
- Output operation voltage (max)
- 208 V
- Waveform
- Pure sine
- Input operation voltage (max)
- 268 V
- Output operation voltage (min)
- 240 V
- UPS topology
- Standby (Offline)
- Typical backup time at full load
- 6 min
- Automatic Voltage Regulation (AVR)
- Yes
- RS-232 ports
- 1
- Alarm clock
- Yes
- Noise Level
- 45 dB
- Product colour
- Black
- Typical switching time
- 2 ms
- Number of IEC320 sockets
- 8
- Warnings
- Keep away from sources of fire and water.
Quick Compare
Product |
APC Smart-UPS uninterruptible power supply (UPS) Line-Interactive 0.45 kVA 280 W 4 AC outlet(s)
|
Infosec E4 Value 1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 3 AC outlet(s)
|
Green Cell UPS14 uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 1800 W 6 AC outlet(s)
|
|
Availability |
|
|
|
|
Price |
€390.05
|
€390.13
|
€390.45
|
€393.95
|
Description |
||||
Width |
432 mm | 145 mm | 440 mm | |
Height |
44 mm | 282 mm | 542 mm | |
Depth |
383 mm | 220 mm | 86.5 mm | |
Weight |
10.2 kg | 8.6 kg | 20.1 kg | |
Package height |
164 mm | |||
Package width |
476 mm | |||
Cables included |
RS-232 | Output power cable, RS-232, Input power cable | ||
Storage relative humidity (H-H) |
0 - 95% | |||
Manual |
Yes | Yes | ||
Operating temperature (T-T) |
0 - 40 °C | 0 - 40 °C | ||
Operating relative humidity (H-H) |
0 - 95% | 20 - 90% | ||
Storage temperature (T-T) |
-15 - 45 °C | |||
Form factor |
Rackmount/Tower | Tower | Rackmount | |
LED indicators |
Battery replacement | |||
Battery technology |
Sealed Lead Acid (VRLA) | Sealed Lead Acid (VRLA) | ||
Battery life (max) |
5 year(s) | |||
Battery capacity |
108 VAh | 9 Ah | 9 Ah | |
Battery recharge time |
5 h | 4 h | ||
Output power |
280 W | 1800 W | ||
Input frequency |
50/60 Hz | 47 - 63 Hz | 45/65 Hz | |
Response time |
4 ms | |||
Display type |
LED | |||
Number of battery cells |
4 | |||
Efficiency |
88% | |||
Input operation voltage (min) |
151 V | 100 V | 110 V | |
Power protection features |
Overcharge | |||
Cold start |
Yes | |||
AC outlets quantity |
4 AC outlet(s) | 3 AC outlet(s) | 6 AC outlet(s) | |
Output power capacity |
0.45 kVA | 1 kVA | 2 kVA | |
Output operation voltage (max) |
240 V | 240 V | ||
Waveform |
Sine | Pure sine | Pure sine | |
Auto-restart |
Yes | |||
AC outlet types |
C13 coupler | C13 coupler | IEC 320 | |
Input operation voltage (max) |
302 V | 240 V | 290 V | |
Audible alarm(s) |
Yes | Yes | ||
Battery voltage |
12 V | 12 V | ||
Output operation voltage (min) |
100 V | 200 V | ||
UPS topology |
Line-Interactive | Double-conversion (Online) | Double-conversion (Online) | |
Typical backup time at full load |
5.9 min | 30 min | ||
Automatic Voltage Regulation (AVR) |
Yes | |||
Automatic battery test |
Yes | |||
Typical backup time at half load |
19.4 min | 9 min | ||
Surge protection |
Yes | |||
Nominal output voltage |
230 V | |||
Output voltage regulation |
-1 - 1% | |||
Operating altitude |
0 - 3000 m | |||
Serial interface type |
RS-232 | RS-232 | ||
Output frequency |
47/63 Hz | 50/60 Hz | ||
Noise Level |
38 dB | 50 dB | ||
Serial ports quantity |
1 | 1 | ||
Maximum current |
10 A | |||
Surge energy rating |
320 J | |||
Power plug |
C14 coupler | |||
Non-operating altitude |
0 - 15000 m | |||
Product colour |
Grey | Black | Black | |
Harmonized System (HS) code |
85078000 | |||
Serial interface |
Yes | Yes | ||
ECO mode |
Yes | |||
Charging current |
1 A | |||
Output voltage Total Harmonic Distortion (THD) |
6% | |||
Hot-swap battery |
Yes | |||
Compliance certificates |
RoHS | RoHS | ||
Total carbon footprint (kg of CO2e) |
484.92 | |||
Audible alarm modes |
Low battery alarm, Overload alarm | Alarm when on battery, Fault, Overload alarm, Low battery alarm | ||
Power factor |
0.8 | |||
Hold time (max) |
8 ms | |||
Hold time (min) |
4 ms | |||
Surge protection features |
Fax | |||
Number of output IEC jumpers |
2 | |||
Crest factor |
3:1 | |||
Rack capacity |
1U | |||
Rack mount kit |
Yes | |||
Input power factor |
0.99 | |||
Number of input phases |
1 | |||
Number of output phases |
1 | |||
Warnings |
Store away from sources of heat and open flame. | |||