Quick Compare
Product |
CyberPower UPS Systems OLS1000ERT2UA 1000 VA, 900 W | CyberPower
|
APC Back-UPS Pro BR1600MI - UPS - 960
|
PowerWalker VFI 2000 ICT IoT uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 2000 W 8 AC outlet(s)
|
APC BACK-UPS PRO 1500
|
Availability |
|
|
|
|
Price |
€524.09
|
€526.04
|
€526.65
|
€531.03
|
Description |
CyberPower UPS Systems OLS1000ERT2UA 1000 VA, 900 W | CyberPower | |||
Warranty |
24 month(s) | |||
Net weight |
13.50 kg | |||
Gross weight |
13.65 kg | |||
WEEE tax |
Yes | |||
Packing quantity |
1.00 pc(s) | |||
Volume (m3) |
0.02 m | |||
Tare weight (kg) |
0.15 kg | |||
Gross depth (mm) |
430.00 mm | |||
Gross width (mm) |
438.00 mm | |||
Gross height (mm) |
88.00 mm | |||
WEE classification |
CL109:5:2017-04-01 | |||
Paper/Pasteboard |
140.00 g | |||
Embeeded battery |
No | |||
Cable length |
1.83 m | 1.83 m | ||
Width |
250 mm | 192 mm | 112 mm | |
Height |
100 mm | 318 mm | 301 mm | |
Depth |
382 mm | 428 mm | 382 mm | |
Plastic (No PET) |
10.00 g | |||
Weight |
10.9 kg | 26 kg | 13 kg | |
Package depth |
225 mm | 330 mm | ||
Package height |
330 mm | 475 mm | 390 mm | |
Package width |
485 mm | 590 mm | 235 mm | |
Package weight |
11.7 kg | 28.5 kg | ||
Number of batteries supported |
6 | |||
Battery type |
APCRBC124 | |||
Cables included |
USB cable | Input power cable, Output power cable, USB cable | Phone (RJ-11), USB cable | |
Storage relative humidity (H-H) |
0 - 95% | 0 - 95% | ||
Manual |
Yes | Yes | Yes | |
Operating temperature (T-T) |
0 - 40 °C | 0 - 45 °C | 0 - 40 °C | |
Operating relative humidity (H-H) |
0 - 95% | 0 - 95% | 0 - 95% | |
Storage temperature (T-T) |
-15 - 45 °C | -15 - 45 °C | ||
Form factor |
Tower | Tower | Tower | |
USB port |
Yes | Yes | Yes | |
LED indicators |
Yes | Yes | ||
Battery technology |
Sealed Lead Acid (VRLA) | |||
Battery life (max) |
5 year(s) | 5 year(s) | ||
Battery capacity |
7 Ah | 187 VAh | ||
Battery recharge time |
16 h | 3 h | 8 h | |
Cooling type |
Passive | Active | ||
Output power |
960 W | 2000 W | 865 W | |
Input frequency |
50/60 Hz | 40/70 Hz | 50/60 Hz | |
USB 2.0 ports quantity |
1 | |||
Response time |
0 ms | |||
Display type |
LCD | LCD | LCD | |
Ethernet LAN (RJ-45) ports |
2 | |||
Efficiency |
98.9% | |||
Input operation voltage (min) |
176 V | 156 V | ||
Power protection features |
Overload | |||
Cold start |
Yes | Yes | ||
AC outlets quantity |
8 AC outlet(s) | 8 AC outlet(s) | 6 AC outlet(s) | |
Output power capacity |
1.6 kVA | 2 kVA | 1.5 kVA | |
Output operation voltage (max) |
240 V | |||
Waveform |
Sine | Pure sine | Sine | |
AC outlet types |
C13 coupler | C13 coupler | Type F | |
Input operation voltage (max) |
294 V | 300 V | 300 V | |
Audible alarm(s) |
Yes | Yes | ||
Battery voltage |
12 V | |||
Output operation voltage (min) |
200 V | |||
UPS topology |
Line-Interactive | Double-conversion (Online) | Line-Interactive | |
Typical backup time at full load |
3.7 min | |||
Warranty card |
Yes | |||
Cabling technology |
10/100/1000Base-T(X) | |||
Automatic Voltage Regulation (AVR) |
Yes | |||
Automatic battery test |
Yes | Yes | ||
Typical backup time at half load |
12.3 min | |||
Surge protection |
Yes | Yes | ||
Nominal input voltage |
230 V | 230 V | ||
Nominal output voltage |
230 V | 230 V | ||
Output frequency regulation |
50/60 Hz | |||
Output voltage regulation |
1% | |||
Operating altitude |
0 - 3000 m | 0 - 3000 m | ||
Serial interface type |
RS-232 | |||
Output frequency |
50/60 Hz | |||
Noise Level |
45 dB | 50 dB | 45 dB | |
Serial ports quantity |
1 | |||
Maximum current |
10 A | |||
Surge energy rating |
509 J | 441 J | ||
Power plug |
C14 coupler | C20 coupler | Type F | |
Non-operating altitude |
0 - 15000 m | 0 - 15000 m | ||
Product colour |
Black | Black | Black | |
Harmonized System (HS) code |
85078000 | 85078000 | 85078000 | |
Sustainability certificates |
Green Premium | |||
Serial interface |
Yes | |||
ECO mode |
Yes | Yes | ||
Charging current |
1.5 A | |||
Hot-swap battery |
Yes | Yes | ||
Producer |
CyberPower | |||
Compliance certificates |
RoHS | |||
Audible alarm modes |
Alarm when on battery, Low battery alarm, Overload alarm | |||
Hold time (max) |
12 ms | |||
Hold time (min) |
10 ms | |||
Surge protection features |
Network | Network | ||
Crest factor |
3:1 | |||
Emergency Power Off (EPO) |
Yes | |||
Number of type F outputs |
6 | |||
Output power factor |
1 | |||
Emergency Power Off (EPO) connector |
Yes | |||
Input power factor |
0.99 | |||
Built-in fan |
Yes | |||
Number of input phases |
1 | |||
Number of output phases |
1 | |||
Efficiency (On-line mode) |
93% | |||
Input current Total Harmonic Distortion (THD) |
5% | |||