Data sheet
- Warranty
- 24 month(s)
- Producer product name
- BK500EI
- Net weight
- 6.32 kg
- Gross weight
- 7.05 kg
- WEEE tax
- Yes
- Packing quantity
- 1.00 pc(s)
- Volume (m3)
- 0.02 m
- Tare weight (kg)
- 0.73 kg
- Gross depth (mm)
- 178.00 mm
- Gross width (mm)
- 368.00 mm
- Gross height (mm)
- 241.00 mm
- WEE classification
- CL109:5:2017-04-01
- Paper/Pasteboard
- 584.00 g
- Embeeded battery
- Yes
- TI weight (kg)
- 2.50 kg
- Plastic (No PET)
- 146.00 g
- Composition of battery
- CL127:KT:2016-12-09
- Classification of battery
- CL126:NE:2016-12-09
- Type of battery
- Accumulator
- Special features
- Data line protection ensures complete protection of your equipment against surges LED display allows easy reading of device status and power conditions
- Producer product family
- APC Back-UPS
- Capacity
- 500 VA
- Palette Qty
- 109 pc(s)
- Producer
- Schneider Electric
Quick Compare
Product |
Green Cell UPS08 uninterruptible power supply (UPS) Line-Interactive 1000 VA 700 W 4 AC outlet(s)
|
PowerWalker VI 1200 LCD/FR Line-Interactive 1.2 kVA 600 W 4 AC outlet(s)
|
Infosec INF_661147 Backup Power Supply UPS X1+ 1300 IEC, 1300VA, 720W, 6× C13
|
Eaton 3S850D uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA 510 W 8 AC outlet(s)
|
Availability |
|
|
|
|
Price |
€154.59
|
€155.35
|
€158.60
|
€159.16
|
Description |
||||
Cable length |
1.5 m | |||
Width |
350 mm | 139 mm | 148 mm | 335 mm |
Height |
160 mm | 195 mm | 178 mm | 86 mm |
Depth |
146 mm | 365 mm | 298 mm | 170 mm |
Weight |
8 kg | 8.9 kg | 7.5 kg | 4.3 kg |
Package height |
292 mm | |||
Package width |
230 mm | |||
Number of batteries supported |
2 | |||
Cables included |
USB cable, Input power cable | |||
Manual |
Yes | |||
Operating temperature (T-T) |
0 - 40 °C | 0 - 40 °C | 0 - 40 °C | |
Operating relative humidity (H-H) |
0 - 90% | 0 - 90% | ||
Form factor |
Tower | Tower | Tower | |
USB port |
Yes | Yes | Yes | |
LED indicators |
Yes | Yes | ||
Battery technology |
Lead-acid | Sealed Lead Acid (VRLA) | ||
Battery capacity |
7 Ah | 7 Ah | 2 x 7 Ah | |
Battery recharge time |
8 h | 6 h | 8 h | |
Cooling type |
Active | |||
Output power |
700 W | 600 W | 720 W | 510 W |
Input frequency |
50/60 Hz | 50/60 Hz | 50/60 Hz | |
USB 2.0 ports quantity |
1 | 1 | 1 | 2 |
Response time |
6 ms | |||
Display type |
LCD | |||
Ethernet LAN (RJ-45) ports |
1 | |||
Input operation voltage (min) |
220 V | 170 V | 162 V | 161 V |
Power protection features |
Short circuit | Overcharge | Over power | Overdischarge |
Cold start |
Yes | Yes | Yes | |
AC outlets quantity |
4 AC outlet(s) | 4 AC outlet(s) | 6 AC outlet(s) | 8 AC outlet(s) |
Output power capacity |
1000 kVA | 1.2 kVA | 1300 VA | 0.85 kVA |
Output operation voltage (max) |
230 V | 230 V | 220 V | 240 V |
Waveform |
Pure sine | Sine | Simulated Sine Wave | |
Auto-restart |
Yes | |||
AC outlet types |
IEC 320 | Type E | IEC C13 | |
Input operation voltage (max) |
240 V | 280 V | 290 V | 284 V |
Audible alarm(s) |
Yes | Yes | ||
Battery voltage |
12 V | 12 V | 12 V | |
Output operation voltage (min) |
23 V | 240 V | 220 V | |
UPS topology |
Line-Interactive | Line-Interactive | Line-Interactive | Standby (Offline) |
Modem (RJ-11) ports |
1 | |||
Typical backup time at full load |
60 min | |||
Automatic Voltage Regulation (AVR) |
Yes | |||
Automatic battery test |
Yes | |||
Typical backup time at half load |
10 min | |||
Surge protection |
Yes | Yes | Yes | |
Nominal input voltage |
230 V | |||
Output frequency regulation |
50 / 60 Hz | |||
Output voltage regulation |
10% | -10 - 10% | ||
Operating altitude |
0 - 3000 m | |||
Serial interface type |
RJ-45 | |||
Output frequency |
50/60 Hz | 50/60 Hz | 50 Hz | |
Noise Level |
45 dB | |||
Maximum current |
10 A | |||
Product colour |
Black | Black | Black | Black |
Harmonized System (HS) code |
85078000 | |||
Safety |
IEC 62040-1; IEC 62040-2 C2; IEC 62040-3; IEC 62040-4; IEC 61643-11 | |||
Serial interface |
Yes | |||
USB port type |
USB Type-B | |||
Hot-swap battery |
No | |||
Compliance certificates |
RoHS | |||
Audible alarm modes |
Alarm when on battery, Fault, Overload alarm, Low battery alarm | |||
Hold time (max) |
4 ms | |||
Surge protection features |
Network | |||
Number of input phases |
1 | |||
Number of output phases |
1 | |||
Warnings |
Use the appliance in well-ventilated areas to avoid overheating. | |||