Prekė detaliau
Charakteristikos
- Width
- 123 mm
- Height
- 220 mm
- Depth
- 400 mm
- Weight
- 10.8 kg
- Number of batteries supported
- 2
- Cables included
- USB cable
- Manual
- Yes
- Operating temperature (T-T)
- 0 - 40 °C
- Operating relative humidity (H-H)
- 20 - 90%
- LED indicators
- Yes
- Battery technology
- Sealed Lead Acid (VRLA)
- Battery capacity
- 8 Ah
- Battery recharge time
- 12 h
- Output power
- 900 W
- Input frequency
- 50/60 Hz
- USB 2.0 ports quantity
- 1
- Input operation voltage (min)
- 220 V
- Power protection features
- Short circuit
- Cold start
- Yes
- AC outlets quantity
- 3 AC outlet(s)
- Output power capacity
- 1500 kVA
- Waveform
- Sine
- AC outlet types
- C13 coupler
- Battery voltage
- 12 V
- Output operation voltage (min)
- 220 V
- UPS topology
- Line-Interactive
- Automatic Voltage Regulation (AVR)
- Yes
- Surge protection
- Yes
- Noise Level
- 45 dB
- Product colour
- Black
- Hold time (max)
- 10 ms
- Number of type F outputs
- 1
Greitas palyginimas
Prekė |
FSP IFP 1000 1000 VA, 600 W
|
Schneider Electric APC Back-UPS | BX750MI | 750 VA | 410 W
|
Digitus DN-170066 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA 900 W
|
Green Cell uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 480 W 4 AC outlet(s)
|
Prieinamumas |
|
|
|
|
Kaina |
104,90 €
|
105,74 €
|
106,27 €
|
107,96 €
|
Aprašymas |
FSP IFP 1000 1000 VA, 600 W | Schneider Electric APC Back-UPS | BX750MI | 750 VA | 410 W | ||
Warranty |
24 month(s) | 24 month(s) | ||
Producer product name |
IFP 1000 | BX750MI | ||
Net weight |
7.18 kg | 5.40 kg | ||
Gross weight |
8.4 kg | 5.90 kg | ||
WEEE tax |
Yes | Yes | ||
Packing quantity |
1 pc(s) | 1.00 pc(s) | ||
Volume (m3) |
0.021181875 m | 0.02 m | ||
Tare weight (kg) |
1.22 kg | 0.50 kg | ||
Gross depth (mm) |
395 mm | 250.00 mm | ||
Gross width (mm) |
275 mm | 197.00 mm | ||
Gross height (mm) |
195 mm | 430.00 mm | ||
WEE classification |
CL109:5:2017-04-01 | CL109:5:2017-04-01 | ||
Paper/Pasteboard |
1220 g | 400.00 g | ||
Embeeded battery |
No | Yes | ||
TI weight (kg) |
2.59 kg | |||
Width |
158 mm | |||
Dimensions (WxDxH) |
130x320x182 mm | |||
Height |
198 mm | |||
Depth |
380 mm | |||
Plastic (No PET) |
100.00 g | |||
Composition of battery |
CL127:KT:2016-12-09 | |||
Classification of battery |
CL126:NE:2016-12-09 | |||
Type of battery |
Accumulator | |||
Weight |
10.1 kg | |||
Producer product family |
APC Back-UPS | |||
Number of batteries supported |
2 | |||
Operating temperature (T-T) |
0 - 40 °C | |||
Operating relative humidity (H-H) |
0 - 95% | |||
Form factor |
Tower | Tower | ||
USB port |
Yes | |||
LED indicators |
Yes | |||
Battery technology |
Sealed Lead Acid (VRLA) | |||
Battery capacity |
9 Ah | 7 Ah | ||
Capacity |
600 W | 750 VA | ||
Palette Qty |
82 pc(s) | |||
Battery recharge time |
8 h | |||
Output power |
900 W | 480 W | ||
Input frequency |
50/60 Hz | 50/60 Hz | ||
USB 2.0 ports quantity |
1 | |||
Response time |
6 ms | |||
Display type |
LED | |||
Ethernet LAN (RJ-45) ports |
2 | |||
Input operation voltage (min) |
162 V | 220 V | ||
Power protection features |
Overload | |||
AC outlets quantity |
4 AC outlet(s) | |||
Output power capacity |
1.5 kVA | 0.75 kVA | ||
Output operation voltage (max) |
240 V | |||
Waveform |
Sine | Pseudo sine | ||
Auto-restart |
Yes | |||
AC outlet types |
Type E / F | |||
Input operation voltage (max) |
290 V | 240 V | ||
Audible alarm(s) |
Yes | |||
Battery voltage |
12 V | 12 V | ||
Output operation voltage (min) |
220 V | |||
UPS topology |
Line-Interactive | Line-Interactive | Line-Interactive | Line-Interactive |
Automatic Voltage Regulation (AVR) |
Yes | Yes | ||
Output voltage regulation |
10% | |||
RS-232 ports |
1 | |||
Output frequency |
50 Hz | |||
Noise Level |
40 dB | |||
Product colour |
Black | Black | ||
USB port type |
USB Type-B | |||
Number of batteries included |
2 pc(s) | |||
Producer |
Schneider Electric | |||
Audible alarm modes |
Battery replacement, Fault, Low battery alarm, Overload alarm | |||
Number of type F outputs |
4 | |||
Warnings |
Do not disassemble the unit housing, there may be a risk of electric shock. | |||