Greitas palyginimas
Prekė |
PowerWalker VFI 1500 ICT IoT Double-conversion (Online) 1.5 kVA 1500 W 4 AC outlet(s)
|
CyberPower OR1000ERM1U uninterruptible power supply (UPS) Line-Interactive 1 kVA 600 W 6 AC outlet(s)
|
APC Smart-UPS SC 450VA - UPS - 280 Wat
|
Prieinamumas |
|
|
|
Kaina |
405,97 €
|
406,75 €
|
412,59 €
|
Aprašymas |
|||
Cable length |
1.83 m | ||
Width |
145 mm | 433 mm | 432 mm |
Height |
220 mm | 44 mm | 44 mm |
Depth |
404 mm | 389 mm | 383 mm |
Weight |
14.3 kg | 13.7 kg | 10.2 kg |
Package depth |
240 mm | ||
Package height |
339 mm | 158 mm | 164 mm |
Package width |
495 mm | 545 mm | 476 mm |
Package weight |
15.7 kg | ||
Number of batteries supported |
3 | 1 | |
Cables included |
USB cable | RS-232 | |
Storage relative humidity (H-H) |
0 - 95% | 0 - 95% | |
Manual |
Yes | ||
Operating temperature (T-T) |
0 - 45 °C | 0 - 40 °C | 0 - 40 °C |
Operating relative humidity (H-H) |
0 - 95% | 0 - 95% | 0 - 95% |
Storage temperature (T-T) |
-15 - 45 °C | -15 - 45 °C | |
Form factor |
Tower | Rackmount | Rackmount/Tower |
USB port |
Yes | Yes | |
LED indicators |
Yes | Operation | Battery replacement |
Battery technology |
Sealed Lead Acid (VRLA) | Sealed Lead Acid (VRLA) | |
Battery life (max) |
5 year(s) | ||
Battery capacity |
9 Ah | 108 VAh | |
Battery recharge time |
3 h | 8 h | 5 h |
Cooling type |
Active | ||
Output power |
1500 W | 600 W | 280 W |
Input frequency |
40/70 Hz | 50/60 Hz | 50/60 Hz |
Response time |
0 ms | 4 ms | |
Display type |
LCD | LCD | |
Ethernet LAN (RJ-45) ports |
1 | ||
Input operation voltage (min) |
160 V | 165 V | 151 V |
Power protection features |
Overload | Overload | |
AC outlets quantity |
4 AC outlet(s) | 6 AC outlet(s) | 4 AC outlet(s) |
Output power capacity |
1.5 kVA | 1 kVA | 0.45 kVA |
Output operation voltage (max) |
240 V | 230 V | |
Waveform |
Pure sine | Sine | Sine |
Auto-restart |
Yes | ||
AC outlet types |
C13 coupler | C13 coupler | C13 coupler |
Input operation voltage (max) |
300 V | 271 V | 302 V |
Audible alarm(s) |
Yes | Yes | |
Battery voltage |
12 V | ||
Output operation voltage (min) |
200 V | 230 V | |
UPS topology |
Double-conversion (Online) | Line-Interactive | Line-Interactive |
Modem (RJ-11) ports |
1 | ||
Typical backup time at full load |
3.5 min | 5.9 min | |
Automatic Voltage Regulation (AVR) |
Yes | Yes | |
Automatic battery test |
Yes | ||
Housing material |
Metal | ||
Typical backup time at half load |
14 min | 19.4 min | |
Surge protection |
Yes | Yes | |
Nominal output voltage |
230 V | ||
Output voltage regulation |
1% | ||
Operating altitude |
0 - 3000 m | 0 - 3000 m | |
Serial interface type |
RS-232 | RS-232 | |
Output frequency |
50/60 Hz | ||
Noise Level |
45 dB | 38 dB | |
Serial ports quantity |
1 | 1 | 1 |
Maximum current |
10 A | ||
Surge energy rating |
810 J | 320 J | |
Power plug |
C14 coupler | C14 coupler | C14 coupler |
Non-operating altitude |
0 - 15000 m | 0 - 15000 m | |
Product colour |
Black | Silver | Grey |
Harmonized System (HS) code |
85078000 | 8504408590 | 85078000 |
Serial interface |
Yes | Yes | |
ECO mode |
Yes | ||
Charging current |
1.5 A | ||
Output voltage Total Harmonic Distortion (THD) |
1% | ||
Hot-swap battery |
Yes | Yes | |
Compliance certificates |
RoHS | RoHS | |
Total carbon footprint (kg of CO2e) |
484.92 | ||
Audible alarm modes |
Fault, Low battery alarm, Overload alarm | Low battery alarm, Overload alarm | |
Power factor |
0.6 | ||
Hold time (max) |
8 ms | ||
Hold time (min) |
4 ms | ||
Surge protection features |
Modem | ||
Number of output IEC jumpers |
2 | ||
Crest factor |
3:1 | ||
Emergency Power Off (EPO) |
Yes | ||
Rack capacity |
1U | 1U | |
Rack mount kit |
Yes | ||
EMI/RFI noise filtering |
Yes | ||
Output power factor |
1 | ||
Emergency Power Off (EPO) connector |
Yes | ||
Input power factor |
0.99 | ||
Built-in fan |
Yes | ||
Number of input phases |
1 | ||
Number of output phases |
1 | ||
Efficiency (On-line mode) |
89% | ||
Input current Total Harmonic Distortion (THD) |
5% | ||
Warnings |
Keep away from sources of fire and water. | Do not disassemble the unit housing, there may be a risk of electric shock. | Use the appliance in well-ventilated areas to avoid overheating. |