Charakteristikos
- Width
- 145 mm
- Height
- 282 mm
- Depth
- 220 mm
- Weight
- 8.6 kg
- Cables included
- Output power cable, RS-232, Input power cable
- Manual
- Yes
- Operating temperature (T-T)
- 0 - 40 °C
- Operating relative humidity (H-H)
- 20 - 90%
- Form factor
- Tower
- Battery technology
- Sealed Lead Acid (VRLA)
- Battery capacity
- 9 Ah
- Battery recharge time
- 4 h
- Input frequency
- 47 - 63 Hz
- Response time
- 4 ms
- Display type
- LED
- Efficiency
- 88%
- Input operation voltage (min)
- 100 V
- Cold start
- Yes
- AC outlets quantity
- 3 AC outlet(s)
- Output power capacity
- 1 kVA
- Output operation voltage (max)
- 240 V
- Waveform
- Pure sine
- AC outlet types
- C13 coupler
- Input operation voltage (max)
- 240 V
- Audible alarm(s)
- Yes
- Battery voltage
- 12 V
- Output operation voltage (min)
- 100 V
- UPS topology
- Double-conversion (Online)
- Typical backup time at full load
- 30 min
- Typical backup time at half load
- 9 min
- Output voltage regulation
- -1 - 1%
- Serial interface type
- RS-232
- Output frequency
- 47/63 Hz
- Noise Level
- 50 dB
- Serial ports quantity
- 1
- Maximum current
- 10 A
- Product colour
- Black
- Serial interface
- Yes
- ECO mode
- Yes
- Charging current
- 1 A
- Output voltage Total Harmonic Distortion (THD)
- 6%
- Compliance certificates
- RoHS
- Audible alarm modes
- Alarm when on battery, Fault, Overload alarm, Low battery alarm
- Power factor
- 0.8
- Crest factor
- 3:1
- Input power factor
- 0.99
- Number of input phases
- 1
- Number of output phases
- 1
- Warnings
- Use the appliance in well-ventilated areas to avoid overheating.
Greitas palyginimas
Prekė |
CyberPower Power Distribution Units PDU41004
|
Ever SINLINE 1200 USB HID Line-Interactive 1.2 kVA 780 W 6 AC outlet(s)
|
PowerWalker VFI 1000 CG PF1 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 1000 W 4 AC outlet(s)
|
Green Cell UPS14 uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 1800 W 6 AC outlet(s)
|
Prieinamumas |
|
|
|
|
Kaina |
378,25 €
|
379,05 €
|
380,13 €
|
382,85 €
|
Aprašymas |
CyberPower Power Distribution Units PDU41004 | |||
Warranty |
24 month(s) | |||
Producer product name |
PDU41004 | |||
Net weight |
2.10 kg | |||
Gross weight |
3.90 kg | |||
WEEE tax |
Yes | |||
Packing quantity |
1.00 pc(s) | |||
Gross depth master carton |
595 mm | |||
Gross width master carton |
360 mm | |||
Gross height master carton |
246 mm | |||
Net weight master carton |
20.8 kg | |||
Tare weight master carton |
0.896 kg | |||
Volume (m3) |
0.01 m | |||
Tare weight (kg) |
1.80 kg | |||
Gross depth (mm) |
250.00 mm | |||
Gross width (mm) |
500.00 mm | |||
Gross height (mm) |
65.00 mm | |||
WEE classification |
CL109:4:2017-04-01 | |||
Paper/Pasteboard |
1300.00 g | |||
Embeeded battery |
No | |||
Package type |
Box | |||
TI weight (kg) |
3.5 kg | |||
Width |
483 mm | 145 mm | 440 mm | |
Dimensions (WxDxH) |
433 x 112 x 44 mm | |||
Height |
88 mm | 221 mm | 542 mm | |
Depth |
320 mm | 397 mm | 86.5 mm | |
Other features |
Real-time Local/Remote Monitoring and Switching Work under High Temperature 1% Measurement Accuracy Digital Real-time Load Display Hot-swappable LCD Design LED Status Indicator Support ENVIROSENSOR PowerPanel Management Software Cord Retention Tray Contro | |||
Plastic (No PET) |
500.00 g | |||
Composition of battery |
CL127:KT:2016-12-09 | |||
Classification of battery |
CL126:PE:2016-12-09 | |||
Type of battery |
Accumulator | |||
Weight |
17 kg | 13 kg | 20.1 kg | |
Producer product family |
Power Distribution Units | |||
Package depth |
472 mm | |||
Package height |
160 mm | 325 mm | ||
Package width |
515 mm | 230 mm | ||
Package weight |
15 kg | |||
Number of batteries supported |
2 | 3 | ||
Cables included |
Input power cable, Output power cable, USB cable | |||
Storage relative humidity (H-H) |
20 - 95% | |||
Manual |
Yes | |||
Operating temperature (T-T) |
0 - 40 °C | 0 - 40 °C | ||
Operating relative humidity (H-H) |
20 - 80% | 20 - 95% | ||
Storage temperature (T-T) |
0 - 40 °C | |||
Form factor |
Rackmount | Tower | Rackmount | |
USB port |
Yes | Yes | ||
Battery technology |
Sealed Lead Acid (VRLA) | |||
Battery capacity |
7 Ah | 7 Ah | 9 Ah | |
Palette Qty |
213 pc(s) | |||
Battery recharge time |
3 h | |||
Cooling type |
Active | |||
Output power |
780 W | 1000 W | 1800 W | |
Input frequency |
50 Hz | 40/70 Hz | 45/65 Hz | |
Display type |
LCD | |||
Number of battery cells |
4 | |||
Efficiency |
89% | |||
Input operation voltage (min) |
160 V | 110 V | 110 V | |
Power protection features |
Overload | |||
Cold start |
Yes | |||
AC outlets quantity |
6 AC outlet(s) | 4 AC outlet(s) | 6 AC outlet(s) | |
Output power capacity |
1.2 kVA | 1 kVA | 2 kVA | |
Output operation voltage (max) |
264 V | 240 V | 240 V | |
Waveform |
Sine | Pure sine | ||
AC outlet types |
C13 coupler | C13 coupler | IEC 320 | |
Input operation voltage (max) |
264 V | 300 V | 290 V | |
Battery voltage |
12 V | 12 V | 12 V | |
Output operation voltage (min) |
184 V | 200 V | 200 V | |
UPS topology |
Line-Interactive | Double-conversion (Online) | Double-conversion (Online) | |
Typical backup time at full load |
4.5 min | |||
Warranty card |
Yes | |||
Automatic Voltage Regulation (AVR) |
Yes | |||
Typical backup time at half load |
12.9 min | |||
Surge protection |
Yes | |||
Output voltage regulation |
1% | |||
International Protection (IP) code |
IP20 | |||
Serial interface type |
RS-232 | |||
Output frequency |
50 Hz | 50/60 Hz | ||
Noise Level |
50 dB | |||
Power plug |
C14 coupler | |||
Product colour |
Black | Black | Black | |
Harmonized System (HS) code |
85078000 | |||
Serial interface |
Yes | |||
USB port type |
USB Type-B | |||
Output voltage Total Harmonic Distortion (THD) |
2% | |||
Power factor |
0.99 | |||
Surge protection features |
Modem | |||
Crest factor |
3:1 | |||
Emergency Power Off (EPO) |
Yes | |||
Rack capacity |
2U | |||
Resource CD |
Yes | |||
EMI/RFI noise filtering |
Yes | |||
Emergency Power Off (EPO) connector |
Yes | |||
Number of input phases |
1 | |||
Number of output phases |
1 | |||
Input current Total Harmonic Distortion (THD) |
1.6% | |||
Warnings |
Do not disassemble the unit housing, there may be a risk of electric shock. | Use the appliance in well-ventilated areas to avoid overheating. | ||