Eaton UPS Ellipse PRO 1600 DIN | Eaton
Prekė detaliau
Charakteristikos
- Warranty
- 36 month(s)
- Net weight
- 11.30 kg
- Gross weight
- 11.80 kg
- WEEE tax
- Yes
- Packing quantity
- 1.00 pc(s)
- Volume (m3)
- 0.01 m
- Tare weight (kg)
- 0.50 kg
- Gross depth (mm)
- 280.00 mm
- Gross width (mm)
- 90.00 mm
- Gross height (mm)
- 400.00 mm
- WEE classification
- CL109:5:2017-04-01
- Paper/Pasteboard
- 400.00 g
- Embeeded battery
- Yes
- TI weight (kg)
- 9.00 kg
- Plastic (No PET)
- 100.00 g
- Composition of battery
- CL127:KT:2016-12-09
- Classification of battery
- CL126:NE:2016-12-09
- Type of battery
- Accumulator
- Palette Qty
- 85 pc(s)
- Producer
- Eaton
Greitas palyginimas
Prekė |
CyberPower CP1600EPFCLCD uninterruptible power supply (UPS) Line-Interactive 1.6 kVA 1000 W 6 AC outlet(s)
|
APC Smart-UPS SC 450VA 230V - 1U Rackmount/Tower
|
Infosec E4 Value 1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 3 AC outlet(s)
|
Green Cell UPS14 uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 1800 W 6 AC outlet(s)
|
Prieinamumas |
|
|
|
|
Kaina |
384,46 €
|
386,97 €
|
389,89 €
|
390,21 €
|
Aprašymas |
||||
Cable length |
1.83 m | |||
Width |
100 mm | 432 mm | 145 mm | 440 mm |
Height |
280 mm | 44 mm | 282 mm | 542 mm |
Depth |
355 mm | 383 mm | 220 mm | 86.5 mm |
Weight |
11 kg | 10.2 kg | 8.6 kg | 20.1 kg |
Package height |
370 mm | 164 mm | ||
Package width |
195 mm | 476 mm | ||
Power source type |
AC | |||
Cables included |
RS-232 | Output power cable, RS-232, Input power cable | ||
Storage relative humidity (H-H) |
0 - 95% | 0 - 95% | ||
Manual |
Yes | Yes | ||
Operating temperature (T-T) |
0 - 40 °C | 0 - 40 °C | 0 - 40 °C | |
Operating relative humidity (H-H) |
0 - 95% | 0 - 95% | 20 - 90% | |
Storage temperature (T-T) |
-15 - 45 °C | -15 - 45 °C | ||
Form factor |
Tower | Rackmount/Tower | Tower | Rackmount |
USB port |
Yes | |||
LED indicators |
Power | Battery replacement | ||
Battery technology |
Sealed Lead Acid (VRLA) | Sealed Lead Acid (VRLA) | Sealed Lead Acid (VRLA) | |
Battery life (max) |
5 year(s) | |||
Battery capacity |
108 VAh | 9 Ah | 9 Ah | |
Battery recharge time |
8 h | 5 h | 4 h | |
Output power |
1000 W | 280 W | 1800 W | |
Input frequency |
50/60 Hz | 50/60 Hz | 47 - 63 Hz | 45/65 Hz |
Response time |
4 ms | |||
Display type |
LCD | LED | ||
Ethernet LAN (RJ-45) ports |
2 | |||
Number of battery cells |
4 | |||
Efficiency |
88% | |||
Input operation voltage (min) |
220 V | 151 V | 100 V | 110 V |
Power protection features |
Overload | |||
Cold start |
Yes | |||
AC outlets quantity |
6 AC outlet(s) | 4 AC outlet(s) | 3 AC outlet(s) | 6 AC outlet(s) |
Output power capacity |
1.6 kVA | 0.45 kVA | 1 kVA | 2 kVA |
Output operation voltage (max) |
240 V | 240 V | ||
Waveform |
Pure sine | Sine | Pure sine | Pure sine |
Auto-restart |
Yes | |||
AC outlet types |
Type F | C13 coupler | C13 coupler | IEC 320 |
Input operation voltage (max) |
240 V | 302 V | 240 V | 290 V |
Audible alarm(s) |
Yes | Yes | ||
Battery voltage |
12 V | 12 V | ||
Output operation voltage (min) |
100 V | 200 V | ||
UPS topology |
Line-Interactive | Line-Interactive | Double-conversion (Online) | Double-conversion (Online) |
Typical backup time at full load |
2.6 min | 5.9 min | 30 min | |
Automatic Voltage Regulation (AVR) |
Yes | |||
Automatic battery test |
Yes | |||
Typical backup time at half load |
9.7 min | 19.4 min | 9 min | |
Surge protection |
Yes | |||
Nominal output voltage |
230 V | |||
Output voltage regulation |
-1 - 1% | |||
Operating altitude |
0 - 3000 m | |||
Serial interface type |
RS-232 | RS-232 | ||
Output frequency |
47/63 Hz | 50/60 Hz | ||
Noise Level |
38 dB | 50 dB | ||
Serial ports quantity |
1 | 1 | ||
Maximum current |
10 A | |||
Surge energy rating |
405 J | 320 J | ||
Power plug |
C14 coupler | |||
Non-operating altitude |
0 - 15000 m | |||
Product colour |
Black | Grey | Black | Black |
Harmonized System (HS) code |
8504408590 | 85078000 | ||
Sustainability certificates |
RoHS | |||
Sustainability compliance |
Yes | |||
Serial interface |
Yes | Yes | ||
ECO mode |
Yes | |||
USB port type |
USB Type A/USB Type-C | |||
Charging current |
1 A | |||
Output voltage Total Harmonic Distortion (THD) |
6% | |||
Hot-swap battery |
Yes | |||
Compliance certificates |
RoHS | RoHS | ||
Total carbon footprint (kg of CO2e) |
484.92 | |||
Audible alarm modes |
Low battery alarm, Overload alarm | Alarm when on battery, Fault, Overload alarm, Low battery alarm | ||
Power factor |
0.8 | |||
Hold time (max) |
8 ms | |||
Hold time (min) |
4 ms | |||
Surge protection features |
Digital Subscriber Line (DSL) | |||
Number of output IEC jumpers |
2 | |||
Replacement battery cartridge |
RBP0142 | |||
Crest factor |
3:1 | |||
Rack capacity |
1U | |||
Rack mount kit |
Yes | |||
Input power factor |
0.99 | |||
Number of input phases |
1 | |||
Number of output phases |
1 | |||
Detachable power cord |
Yes | |||
Warnings |
Use the appliance in well-ventilated areas to avoid overheating. | Use the appliance in well-ventilated areas to avoid overheating. | Do not disassemble the unit housing, there may be a risk of electric shock. | Keep away from sources of fire and water. |